Connecting
PTP Alignment
Alignment check
Checking signal…
—Checking radio link
Field
Live signal
Waiting for the first link measurement.
Current SNR—
Session best—
From best—
Signal quality guide
Aim for a steady 25 dB SNR or higher. The dashed line marks the target.
| SNR | Signal quality |
|---|---|
| Below 10 dB | Very weak |
| 10–19 dB | Weak |
| 20–24 dB | Usable |
| 25 dB and up | Target range |
Point toward the other dish
Use true north in your compass app.
Field → Office
—Edit radio locations
Alignment guide
Use the same receiver to compare moves on either dish. Keep the other dish fixed.
Manual alignment instructions
- Rough aim. Use the true-north compass headings. Select a receiver with live SNR. Use Office if Field shows Signal unknown.
- Sweep left and right. Stand behind the dish. Mark the bracket position and tap Mark starting SNR. Choose an arrow, move slightly, then tap Measure move. Hold still for two readings. Return to the mark before testing the opposite direction.
- Sweep up and down. Keep the best left/right position, mark it, then test both tilt directions. Use small, equal moves.
- Repeat and tighten. Repeat on the other dish. Keep the highest steady SNR, then check that it holds while tightening the mount.
- Left / Right
- Turn the dish around the pole.
- Up / Down
- Tilt the dish face higher or lower.
Receiver SNR —
Waiting for two live SNR readings.